Specifications:
Functions | Range | Resolution | Accuracy | BT510 | BT520 | BT521 |
Battery Resistance / Strap Resistance1 | 3 mΩ | 0.001 mΩ | 1% + 8 | ● | ● | ● |
30 mΩ | 0.01 mΩ | 0.8% + 6 | ● | ● | ● | |
300 mΩ | 0.1 mΩ | 0.8% + 6 | ● | ● | ● | |
3000 mΩ | 1 mΩ | 0.8% + 6 | ● | ● | ● | |
VDC | 6 V | 0.001 V | 0.09% + 5 | ● | ● | ● |
60 V | 0.01 V | 0.09% + 5 | ● | ● | ● | |
600 V | 0.1 V | 0.09% + 5 | ● | ● | ● | |
1000 V | 1 V | 0.09% + 5 | ● | |||
VAC (45 Hz to 500 Hz with 800 Hz filter) | 600 V | 0.1 V | 2% + 10 | ● | ● | ● |
Frequency (displayed with VAC and AAC)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | ● | ● | ● |
AC voltage ripple (20 KHz Max) | 600 mV | 0.1 mV | 3% + 20 | ● | ● | ● |
6000 mV | 1 mV | 3% + 10 | ● | ● | ● | |
ADC/AAC (with accessory Fluke i410) | 400 A | 1 A | 3.5% + 2 | ● | ||
Temperature | 0°C to 60°C | 1°C | 2°C (4°F) | ● | ||
Meter mode | 999 records for each measurement position with time stamp | |||||
Sequence mode | Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp | |||||
1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz. 2. Trigger level VAC: 10 mV, AAC: 10 A |
||||||
Measurement Modes | BT510 | BT520 | BT521 | |||
Resistance (mΩ) | ● | ● | ● | |||
Battery voltage | ● | ● | ● | |||
Voltage DC | ● | ● | ● | |||
Voltage AC and frequency (Hz) | ● | ● | ● | |||
Ripple volt | ● | ● | ● | |||
Temperature of negative battery post | ● | |||||
DC and AC current (and frequency) | ● | |||||
DMM mode | ● | ● | ● | |||
Sequence mode | ● | ● | ● | |||
Discharge measurement mode | ● | ● | ● | |||
Automatic measurement save | ● | ● | ● | |||
Wireless commumcation | ● | |||||
Memory view | ● | ● | ● | |||
General Specifications | ||||||
Size (H x W x D) | 22 x 10.3 x 5.8 cm (9 x 4 x 2 in) | |||||
Weight | 850 g (1.9 lb) | |||||
Screen dimensions | 7.7 x 5.6 cm (3 x 2.2 in) | |||||
Interface | USB mini | |||||
Warranty | 3 years | |||||
Environment Specifications | ||||||
Operating temperature | 0°C to 40°C | |||||
Storage temperature | -20°C to 50°C | |||||
Lithium-ion battery charging temperature | 0°C to 40°C | |||||
Operating humidity | Non-condensing (10°C) | |||||
≤ 80% RH (at 10°C to 30°C) | ||||||
≤ 75% RH (at 30°C to 40°C) | ||||||
Operating altitude | Sea level to 2000 meters | |||||
Storage altitude | Sea level to 12,000 meters | |||||
IP rating | IP40 | |||||
Radio | FCC Class A | |||||
Vibration requirements | MIL-PRF-28800F: Class 2 | |||||
Drop test requirements | 1 meter | |||||
Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | |||||
Safety compliance | 600 V CAT III | |||||
EMC | IEC 61326 | |||||
ROHS | China, Europe | |||||
Protection class 2 | Pollution Degree II | |||||
Battery compliance | UN38.3 | |||||
UL2054 | ||||||
IEC62133 | ||||||
2 G per IEC68-2-26, 25 G, and 29 |