Uganda Make an Enquiry
Fluke Networks DSX2-8000 Versiv 2 CableAnalyzer with Integrated Wi-Fi

Product Features:

  • DSX2-8000 comes with integrated WiFi functionality for connecting wirelessly with Fluke Network's LinkWare Live
  • Capable of testing and certifying twisted pair Cat 5e, 6, 6A, 8 and Class I/II cabling with limits up to 2 GHz
  • Has a level VI/2G accuracy (2 GHz)
  • Versiv 2 enables users to accomplish more than ever with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even locate tester from any smart device
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Performance:

  • Eight second Cat 6A test time contributes to the fastest way to gain certification
  • Graphically displays the source of failures including crosstalk and distance to shield faults for faster troubleshooting
  • Manage up to 12,000 Cat 6A test results with full graphics
  • Capacitive touchscreen allows quick tester setup with easily selectable cable types, standards and testing parameters
  • Over 1 billion links reported on LinkWare PC management software

Standards:

  • Compliant with ANSI/TIA-1152-A Level 2G and proposed standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to 2000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) - IEEE 802.3bt, ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
  • TCL and ELTCTL measurements compliant to IEC 61935-1-1 (Draft)
  • Screen continuity along path of cabling

You might also be interested in

See All
© 2024 Energy Monitoring Ltd. All Rights Reserved.